Interpret as HPCR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (RTC_EN_0)RTC_EN 0 (HPTA_EN_0)HPTA_EN 0 (DIS_PI_0)DIS_PI 0 (PI_EN_0)PI_EN 0 (PI_FREQ_0)PI_FREQ0 (HPCALB_EN_0)HPCALB_EN 0 (HPCALB_VAL_0)HPCALB_VAL0 (HP_TS_0)HP_TS 0BTN_CONFIG 0 (BTN_MASK)BTN_MASK

HPCALB_EN=HPCALB_EN_0, PI_EN=PI_EN_0, PI_FREQ=PI_FREQ_0, HPCALB_VAL=HPCALB_VAL_0, DIS_PI=DIS_PI_0, HPTA_EN=HPTA_EN_0, HP_TS=HP_TS_0, RTC_EN=RTC_EN_0

Description

SNVS_HP Control Register

Fields

RTC_EN

HP Real Time Counter Enable

0 (RTC_EN_0): RTC is disabled

1 (RTC_EN_1): RTC is enabled

HPTA_EN

HP Time Alarm Enable When set, the time alarm interrupt is generated if the value in the HP Time Alarm Registers is equal to the value of the HP Real Time Counter

0 (HPTA_EN_0): HP Time Alarm Interrupt is disabled

1 (HPTA_EN_1): HP Time Alarm Interrupt is enabled

DIS_PI

Disable periodic interrupt in the functional interrupt

0 (DIS_PI_0): Periodic interrupt will trigger a functional interrupt

1 (DIS_PI_1): Disable periodic interrupt in the function interrupt

PI_EN

HP Periodic Interrupt Enable The periodic interrupt can be generated only if the HP Real Time Counter is enabled

0 (PI_EN_0): HP Periodic Interrupt is disabled

1 (PI_EN_1): HP Periodic Interrupt is enabled

PI_FREQ

Periodic Interrupt Frequency Defines frequency of the periodic interrupt

0 (PI_FREQ_0): - bit 0 of the HPRTCLR is selected as a source of the periodic interrupt

1 (PI_FREQ_1): - bit 1 of the HPRTCLR is selected as a source of the periodic interrupt

2 (PI_FREQ_2): - bit 2 of the HPRTCLR is selected as a source of the periodic interrupt

3 (PI_FREQ_3): - bit 3 of the HPRTCLR is selected as a source of the periodic interrupt

4 (PI_FREQ_4): - bit 4 of the HPRTCLR is selected as a source of the periodic interrupt

5 (PI_FREQ_5): - bit 5 of the HPRTCLR is selected as a source of the periodic interrupt

6 (PI_FREQ_6): - bit 6 of the HPRTCLR is selected as a source of the periodic interrupt

7 (PI_FREQ_7): - bit 7 of the HPRTCLR is selected as a source of the periodic interrupt

8 (PI_FREQ_8): - bit 8 of the HPRTCLR is selected as a source of the periodic interrupt

9 (PI_FREQ_9): - bit 9 of the HPRTCLR is selected as a source of the periodic interrupt

10 (PI_FREQ_10): - bit 10 of the HPRTCLR is selected as a source of the periodic interrupt

11 (PI_FREQ_11): - bit 11 of the HPRTCLR is selected as a source of the periodic interrupt

12 (PI_FREQ_12): - bit 12 of the HPRTCLR is selected as a source of the periodic interrupt

13 (PI_FREQ_13): - bit 13 of the HPRTCLR is selected as a source of the periodic interrupt

14 (PI_FREQ_14): - bit 14 of the HPRTCLR is selected as a source of the periodic interrupt

15 (PI_FREQ_15): - bit 15 of the HPRTCLR is selected as a source of the periodic interrupt

HPCALB_EN

HP Real Time Counter Calibration Enabled Indicates that the time calibration mechanism is enabled.

0 (HPCALB_EN_0): HP Timer calibration disabled

1 (HPCALB_EN_1): HP Timer calibration enabled

HPCALB_VAL

HP Calibration Value Defines signed calibration value for the HP Real Time Counter

0 (HPCALB_VAL_0): +0 counts per each 32768 ticks of the counter

1 (HPCALB_VAL_1): +1 counts per each 32768 ticks of the counter

2 (HPCALB_VAL_2): +2 counts per each 32768 ticks of the counter

15 (HPCALB_VAL_15): +15 counts per each 32768 ticks of the counter

16 (HPCALB_VAL_16): -16 counts per each 32768 ticks of the counter

17 (HPCALB_VAL_17): -15 counts per each 32768 ticks of the counter

30 (HPCALB_VAL_30): -2 counts per each 32768 ticks of the counter

31 (HPCALB_VAL_31): -1 counts per each 32768 ticks of the counter

HP_TS

HP Time Synchronize

0 (HP_TS_0): No Action

1 (HP_TS_1): Synchronize the HP Time Counter to the LP Time Counter

BTN_CONFIG

Button Configuration

BTN_MASK

Button interrupt mask